GENERAL PHOTONICS CORP. PSY-101 REPAIR and GENERAL PHOTONICS CORP. PSY-101 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the GENERAL PHOTONICS CORP. PSY-101. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GENERAL PHOTONICS CORP. PSY-101 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Polarization Meter?
Shop for Comparable Products on our
 used Polarization Meter page or new Polarization Meter page

 
   GENERAL PHOTONICS CORP. PSY-101   Description / Specification:    
GENERAL PHOTONICS CORP. PSY-101 PolaFlex Polarization Synthesizer/Analyzer

The General Photonics PSY-101 is a turn-key instrument that can generate and maintain any desired state of polarization (SOP), regardless of the input SOP. It combines General Photonics’ patented polarization controller, in-line polarimeter, and control algorithm into an instrument that functions as both a deterministic polarization state generator and a polarization analyzer. It can scan through 6 distinct SOPs (0°, 90°, ±45°, RHC and LHC) sequentially with user defined speed for Mueller matrix calculations, or select any of the 6 states with the touch of a button. It also functions as a polarization scrambler, generating random SOP scans with user-defined scanning speed. Specifications; Operating Wavelength Range: 1550 ± 50 nm. Insertion Loss: 1.2 dB typical. SOP tracking accuracy: 0.5º. SOP tracking time (trace mode): 3 ms/degree. SOP measurement accuracy: ± 1%. Target SOP resolution: 0.1º. DOP accuracy: ± 2%. Input Stokes parameter resolution: 0.01. Optical power accuracy: ± 0.25 dB. Return loss: 55 dB. PDL: <0.25 dB. PMD: <0.1 ps. Operating power range: -15 dBm to 10 dBm. Optical power damage threshold: 300 mW. Communication Interfaces: RS-232, USB, Ethernet, GPIB.



 

Standard Calibration $955.00 *
*This is a Web introductory price for one calibration of the GENERAL PHOTONICS CORP. PSY-101. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your GENERAL PHOTONICS CORP. PSY-101 REPAIR and/or GENERAL PHOTONICS CORP. PSY-101 PolaFlex Polarization Synthesizer/Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: